PNI CT60 wireless thermostat for thermal power plants, lighting display, daily programs
Wireless thermostat, measuring step 0.1 ° CThe PNI CT60 wireless thermostat is very accurate in measuring temperature and turns the heating system on and off based on a temperature limit and a preset time period. The thermostat has 3 operating modes: Scheduled , Manual and Holiday (anti-freeze). In programmed mode, 4 operating periods can be set for each day of the week. | |
Schedule by dayFor each day of the week you can set a maximum of 4 time periods , each with its own temperature limit. Thus, you can have different programs every day, depending on the time of departure or arrival at home. Example of 4 time periods in a day: |
|
| Parameter setting menuThe advanced settings menu allows you to set parameters for different functions: Hysteresis, anti-freeze temperature, child protection function, open window function, reset, etc. |
Key lock functionIf the child protection function has been activated in the advanced settings, the thermostat keys will lock as soon as the screen backlight turns off to prevent inadvertent temperature change. |
|
| Anti-freeze functionWith the anti-freeze function you can leave the boiler quietly on account of the smart thermostat PNI CT60. From the advanced settings menu, set a temperature level between 5 ° C and 15 ° C, a temperature that will be maintained throughout your absence. |
Open window function (OWD)If the QWD function has been activated from the advanced settings, the thermostat will turn off the heating if the room temperature drops suddenly (adjustable level). This sudden drop in temperature occurs when a window or door is opened while the boiler is operating. The OP icon appears on the screen. The device will return to its original operating mode after 30 minutes. |
|
| PairingThe two units, transmitter and receiver, communicate wirelessly, via radio waves, while the receiver connects via wire to the boiler. As the product must be connected to a 230V mains supply and to heating equipment, installation must only be carried out by qualified personnel. The two units come paired from the factory. |
Video presentation |
|
PNI Wireless Thermostat CT60 for The Central Heating System, Hysteresis 0 1 UK |
| Product identification | |
| Product code | PNI-CT60 |
| General | |
| Product type | Wireless thermostat |
| Designed for | Heating systems |
| Compatible brand | Universal |
| Installation | Desk / wall |
| Material | ABS |
| Color | White |
| Connectivity | - Wireless between the two units: 868 MHz radio - Wired to the boiler |
| Input voltage type | Central unit: AAA batteries Receiver unit: 230V mains |
| Functions | - Daily program: 4 time zones per day - Weekly program: Monday - Sunday - Local temperature control - Mobile central unit - Anti-freeze - Open window detection - Child protection |
| Operating parameters | - Set temperature range: 5 - 35°C - Desired temperature setting step: 0.5°C - Measured temperature range: 0 - 50°C - Unit of measurement: Degrees Celsius - Sensor sensitivity: ± 0.1°C - Hysteresis (Dead Zone): 0.2 °C |
| Configurable parameters | - Internal temperature sensor calibration - Minimum and maximum set temperatures - Anti-freeze temperature - Hysteresis - Parameters - open window |
| Communication frequency | 868 MHz |
| Central unit features | |
| Power | 2 LR3/AAA batteries (not included) |
| Display | Yes, illuminated |
| Display parameters | - Measured temperature (in the room) - Set temperature - Current time - Current program - Day of the week - Operating mode |
| Mounting surface | Wall / Desk |
| Communication frequency | Wireless / Radio - 868 MHz |
| Receiver unit features | |
| Mounting surface | Wall |
| Power | 230VAC 50/60Hz |
| Central control type | NO/NC relay without potential (de-energized) |
| Relay controllable circuit parameters (maximum) | 12-240V AC/DC, 10 Amps |
| Package contains | |
| Central unit | Yes |
| Receiver unit | Yes |
| Mounting accessories | Screws |